Machineryline » Recambios » MTU recambios Case Caterpillar Deutz Hitachi JCB Komatsu Kubota Liebherr New Holland Volvo » MTU piezas del motor » MTU motores » MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset »

MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset

PDF
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset - Machineryline
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset | Imagen 1 - Machineryline
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset | Imagen 2 - Machineryline
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset | Imagen 3 - Machineryline
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset | Imagen 4 - Machineryline
MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset | Imagen 5 - Machineryline
¿Le interesa el anuncio?
1/5
PDF
1 €
Precio neto
≈ 1,13 US$
≈ 1.061 CLP
1,24 €
Precio bruto
Contacte con el vendedor
Tipo: motor
Referencia IAM: 20V4000L64
Referencia OEM: 20V4000GS, 20V4000L64 FNER
Tipo de pieza de repuesto: pieza de recambio original
Año de fabricación: 2020-06
Ubicación: Austria Hörsching7279 km to "United States/Columbus"
Id. de stock del vendedor: 20V4000L64
Fecha de publicación: más de 1 mes
Descripción
Potencia de motor: 2500 Hp (1838 kW)
Número de cilindros: 2
Tipo de motor: tipo V
Turbo
Combustible: gas
Euro: 6
Intercooler
Volumen del motor: 95.400 cm³
Motor
Combustible: gas
Turbo
Intercooler
Euro: Euro 6
Estado
Estado: nuevo
Garantía:: 3 meses

Información adicional — MTU FNER gas 20V4000L64 motor para MTU 20V4000GS gas genset

Español
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
Mostrar todo el comentario
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
MTU Gas Generator set 2020 Brand New Zero Hour machine for sale

Condition: Brand New still in factory packaging
Model: 20V4000L64FNER
Volts: 11kV (11000 V)
Power rating: 2535 kWel
Frequency: 50hz
Speed: 1500 RPM

Engine:
Engine Model 20V4000L64FNER
Version 93800052350-V04-en-GB
Number of cylinders /
configuration 20V
Engine speed 1500 r/min
Bore 170 mm
Stroke 210 mm
Displacement 95.3 L
Lube oil Capacity 350 L
Exhaust gas emissions
NOx, stated as NO2
(dry, 5% O2)
< 250 mg/m³ i.N
CO (dry, 5 % O2) < 1000 mg/m³ i.N

Open skid mounting.

containerised solution available as well:
MTU 20V4000L64 powered by
❖ MTU gas genset of electrical power 2535kWe, 11kV,
50Hz , Pf=1, powered by MTU engine 20V4000L64
❖ ISO 40' High Cube Container
❖ Re-cooling system for engine and mixture cooling
circuit (without heat recovery)
❖ Generator output field including customer ‘s
connection
❖ MMC (MTU Module Control) for system control,
regulating ,diagnosis and protection

Features of Container version:
❖ Full transportability of the system (Rail, Road, Sea)
❖ Lloyd's CSC-certified (Convention Safety Container) for
trouble-free conventional transport (Rail, Road, Sea)
and stackable storage of the modules
❖ Plug & Play solution for the ease of “On site”
installation and operation
❖ Versatile use of the gensets (different operating
conditions)
❖ Weather-proof
❖ Minimum external dimensions, ISO 40’HQ container
❖ Proven tested design (Extensive testing before launch
as standard products)
❖ Combinable optional packages to suit various
demands
❖ Environment friendly provision (e.g. low noise level,
container floor sealed against leaking oil and water,
optional catalytic converter and CHP unit)

MTU Interface Panel (MIP):
Mounted directly on the base frame of all MTU
systems, the MTU Interface Panel (MIP) manages
engine and generator operation. It also controls
paralleling and synchronizing with other sources
of electricity, such as the utility or other generator
sets, and provides remote access and software
interfacing capabilities.
• Genset Control PLC
• Interface to Engine Control Unit ECU
• Interface to Alternator
• Bus interface to external (Modbus)
• On-base components cabled to MIP

MTU Module Control (MMC):
MTU’s highly customizable solution—the MTU
Module Control (MMC)—seamlessly links with
the MIP engine and generator set controls by
cable, making all vital data and functions
accessible to the operator from one convenient
location.
• Operator interface
• DC power supply
• Data Logging capability
• Remote connection to MTU available
• Control of off base components

The MIP/MMC consolidates the following controls and functions:

Generator Set Controls
• Starter Battery Charger
• Gas train control
• Engine oil system (refilling)
• I/O’s (Inputs/Outputs), auxiliary
drives
• Parallel/Island operation
• Load sharing
• PLC (Programmable Logic
Controller)
• AVR (Automatic Voltage
Regulator)
• Energy-Measure-Module –
controls
Engine Control Unit (ECU)
• Gas supply (mixture/lambda)
• Throttle / speed control
• Ignition control
• Turbo bypass
• Knocking detection / control
• Engine sensors / monitoring
• Emission sensor (NOx)
• Start / stop procedure
Accessory Controls
• Alarm system
• Data logging
• Visualization (webserver)
• MMC/MCS interfaces
(Ethernet)
• Customer interfaces (ex.
Modbus)
• HMI touchscreen
• Remote monitoring and
diagnostic
Importante
Esta oferta es de carácter informativo. Para obtener más detalles, póngase en contacto con el vendedor.
Consejos de compra
Consejos de seguridad
Verificación del vendedor

Si decide comprar maquinaria a un precio inferior, póngase en contacto con el verdadero vendedor. Recopile toda la información que le sea posible sobre el propietario de la maquinaria. Una forma de engaño es presentarse como empresa. En caso de sospecha, infórmenos mediante el formulario de comentarios y sugerencias para que lo comprobemos.

Comprobación de precios

Antes de confirmar una compra, revise detenidamente varias ofertas de venta para ver cuál es el precio medio del equipo elegido. Si el precio de la oferta que le interesa es mucho menor que el de ofertas similares, piénselo dos veces. Una diferencia de precio significativa puede conllevar a defectos ocultos o a un intento de fraude por parte del vendedor.

No compre productos cuyo precio diste mucho del precio medio de equipos similares.

No acepte compromisos dudosos o mercancías con prepago. Si no lo tiene claro, no dude en solicitar aclaraciones, pida fotos adicionales y documentos del equipo, compruebe la autenticidad de los mismos y pregunte todo lo necesario.

Prepago dudoso

Esta es la forma más habitual de fraude. Ciertos vendedores pueden requerir una cantidad del pago por adelantado en concepto de «reserva» de su compra. Así, los estafadores perciben grandes cantidades de dinero y después desaparecen sin dejar huella.

Hay varios tipos de fraude, que detallamos:
  • Transferencia de prepago a la tarjeta
  • No realice un pago por adelantado sin documentación que confirme el proceso de transferencia de dinero, si durante la comunicación con el vendedor ha surgido alguna duda.
  • Transferencia a una cuenta «fiduciaria»
  • Dicha solicitud debe alarmarle, ya que en la mayoría de los casos se trata de fraudes.
  • Transferencia a una cuenta de una empresa con un nombre similar
  • Tenga cuidado, ya que los estafadores pueden ocultarse tras la identidad de empresas reconocidas, realizando modificaciones mínimas en su nombre. No transfiera dinero si tiene dudas sobre el nombre de la empresa.
  • Sustitución de sus propios datos en la factura de una empresa real
  • Antes de realizar una transferencia, asegúrese de que los datos especificados sean correctos y que aludan a la empresa en cuestión.
¿Detectó algún fraude?
Infórmenos de lo sucedido
Consejos de seguridad
PDF
¿Vende vehículos o maquinaria?
¡Hagalo con nosotros!
Anuncios similares
MTU 20V4000L64FNER motor para Rolls-Royce MTU 20V4000L64FNER MTU 20V4000L64FNER motor para Rolls-Royce MTU 20V4000L64FNER MTU 20V4000L64FNER motor para Rolls-Royce MTU 20V4000L64FNER
3
1 € ≈ 1,13 US$ ≈ 1.061 CLP
20V4000L64FNER 20V4000GS, 20V4000L64 FNER
gas
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
D2676LE423 D2676LE423, i6-800
diésel
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
D2842LE602 D2842 LE602
diésel
Austria, Hörsching
Contacte con el vendedor
Caterpillar MWM motor para Caterpillar MWM TCG2020V16
1
1 € ≈ 1,13 US$ ≈ 1.061 CLP
MWM TCG2020V16
gas
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
D2862LE476 D2862LE476, V12-1900
diésel
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
D2862LE496 V12-2000
diésel
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
MWM TCG2032V16
gas
Austria, Hörsching
Contacte con el vendedor
Caterpillar MWM TCG2020V20 2MW 50Hz motor para Caterpillar MWM TCG2020V20
1
1 € ≈ 1,13 US$ ≈ 1.061 CLP
MWM TCG2020V20 2MW 50Hz ; CG170-20;
gas
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
D2842LE410,D2842LE404
diésel
Austria, Hörsching
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
J624 JMS624 Jenbacher JMS 624 GS-NL
gas
Austria, Hörsching
Contacte con el vendedor
JB Jenbacher JGS620 gas genset motor para Jenbacher JGS620 JB Jenbacher JGS620 gas genset motor para Jenbacher JGS620 JB Jenbacher JGS620 gas genset motor para Jenbacher JGS620
3
1 € ≈ 1,13 US$ ≈ 1.061 CLP
JGS620,JENBACHER JMS 620 GS-N. L JGS620,
gas
Austria, Hörsching
Contacte con el vendedor
MTU 12V4000 motor
1
VÍDEO
Precio a consultar
12V4000 T94L
EE. UU., New York
Contacte con el vendedor
1 € ≈ 1,13 US$ ≈ 1.061 CLP
MWM TCG2032V16 gas modular power plant
gas
Finlandia, Helsinki
Contacte con el vendedor
Precio a consultar
G3516, G3612, G3616
gas
EE. UU., New York
Contacte con el vendedor
Precio a consultar
1104D-E44TA-NR84949
diésel
Chequia
Contacte con el vendedor
Precio a consultar
12v4000s81
EE. UU., New York
Contacte con el vendedor
Precio a consultar
diésel
Chequia
Contacte con el vendedor
MTU motor para Sandvik TORO 1400
1
Precio a consultar
12.7 III STD L 325HP
EE. UU.
Contacte con el vendedor
Precio a consultar
175-5289, 357-7050, 561-2197, 10R-6702
EE. UU., New York
Contacte con el vendedor
Precio a consultar
TD 2.9 L4
diésel
Chequia
Contacte con el vendedor